Part Number Hot Search : 
V470M PTN3501 CXXXX MMBZ5240 C245M NTE746 ZB4BG4 ST7LITE2
Product Description
Full Text Search
 

To Download 700S-CF Datasheet File

  If you can't view the Datasheet, Please click here to try to view without PDF Reader .  
 
 


  Datasheet File OCR Text:
 Contactors & Control Relays
Safety Control Relays
700S-CF Specifications Conformity to Standards
IEC 60947-5-1 IEC 60947-5-1 Annex L -- Special Requirements for Mechanically Linked Contact Elements EN50011, EN50005, EN50022 UL 508 VDE 0660
Description
Bulletin 700S-CF Safety Control Relays provide mechanically linked, positively guided contacts, which are required in feedback circuits for modern safety applications. The positively guided N.C. auxiliary contacts will not change state if a N.O. contact welds. Consult your local sales office or price list for pricing information.
CSA 22.2 No. 14
Approvals
SUVA Third-Party Certified CE Certified CSA Certified UL Listed (File No. E14840, Guide No. NKCR) C-Tick not required
Features
* Positively guided/mechanically linked auxiliary contacts * Front-mounted auxiliary contact: - Permanently fixed - Protective cover to prevent manual operation - Red contact housing for easy identification - Incorporates IEC 60947-5-1 "Mechanically Linked" symbol * AC and DC operating coils * SUVA third-party certification
Your order must include:
* Catalogue number of the relays required, complete with coil suffix. * Catalogue number of adder decks, timers and accessories required. * If required, the part number of replacement coils.
9-17
Contactors & Control Relays
Safety Control Relays
700S-CF Product Selection Type CF Control Relays -- 8-Pole AC Coil Voltage
AC-12
AC-15
Connection Diagrams
Contacts
Ith [A]
40C 60C 24/ 48V
Ie [A]
120V 240V 400V 500V 600V 690V
A1 K1 A2 14 22 34 44
Main Contacts
13 21 33 43
Auxiliary Contacts
53 61 71 81
NO
NC
Catalogue Number !
4
54 53 62 61 72 71 82 83
4
700S-CF440C
Main Contacts
20
20
10
10
10
6
2.5
1
1
A1 K1 A2 14 22 34 44 13 21 33 43
5
54 53 62 61 72 73 84 83
3
700S-CF530C
Adder Deck Contacts
A1
13
21
33
43
10
6
6
6
5
3
1.6
1
1
K1 A2 14 22 34 44
6
54 62 74 84
2
700S-CF620C
! All Catalogue Numbers are factory-stocked.
AC Coil Voltage Code
The Catalogue Number is incomplete. Select a coil voltage code from the table below to complete the Catalogue Number. Example: 120V 60 Hz: Catalogue Number 700S-CF440C becomes Catalogue Number 700S-CF440DC. Voltage 50 Hz 60 Hz 50/60 Hz 12 R Q - 24 K J KJ 230240 VA - - 32 V - - 36 W V - 42 X - - 48 Y X KY 100 KP - KP 100110 - KP - 380400 N - - 110 D - KD 120 P D - 400415 G - - 127 S - - 200 KG - KG 200220 L KG KL 208 - H - 208240 - L - 220230 F - KL
Voltage 50 Hz 60 Hz 50/60 Hz
230 - - KF
240 T A KA
277 - T -
347 - I -
380 - E -
400 - - KN
440 B N KB
480 - B -
500 M - -
550 C - -
600 - C -
9-18
Contactors & Control Relays
Safety Control Relays
700S-CF Product Selection Type CF Control Relays -- 8-Pole DC Coil Voltage
AC-12
AC-15
Connection Diagrams
Contacts
Ith [A]
40C 60C 24/ 48V
Ie [A]
120V 240V 400V 500V 600V 690V
A1 K1 A2 14 22 34 44
Main Contacts
13 21 33 43
Auxiliary Contacts
53 61 71 81
NO
NC
Catalogue Number !
4
54 53 62 61 72 71 82 83
4
700S-CF440C
Main Contacts
20
20
10
10
10
6
2.5
1
1
A1 K1 A2 14 22 34 44 13 21 33 43
5
54 53 62 61 72 73 84 83
3
700S-CF530C
Adder Deck Contacts
A1
13
21
33
43
10
6
6
6
5
3
1.6
1
1
K1 A2 14 22 34 44
6
54 62 74 84
2
700S-CF620C
! All Catalogue Numbers are factory-stocked.
DC Coil Voltage Code
The Catalogue Number is incomplete. Select a coil voltage code from the table below to complete the Catalogue Number. Example: 24V DC: Catalogue Number 700S-CF440C becomes Catalogue Number 700S-CF440ZJC. Voltage Standard With diode suppressor 9 ZR -- 12 ZQ -- 24 ZJ DJ 36 ZW -- 48 ZY -- 60 ZZ -- 64 ZB -- 72 ZG -- 80 ZE -- 110 ZD -- 115 ZP -- 125 ZS -- 220 ZA -- 230 ZF -- 250 ZT --
9-19
Contactors & Control Relays
Safety Control Relays
100S-C and 700S-CF General
Catalogue Number 700S-CF Contact Ratings -- NEMA Minimum Contact Rating 17V 24V Contact Ratings -- IEC AC-15 (solenoids, contactors) at rated voltage 48V 120V 240V 400V 480V/500V 600V 690V 40C AC-12 (Non-inductive, or slightly inductive loads, resistance furnaces) 60 C Ith 230V 400V 690V Switching DC Loads 24V DC-12
L
Mechanically Linked Contacts Aux. Contact (Frontmounted) A600, Q600 Location of welded N.O. contacts Main Front aux. 6A 6A 6A 5A 3A 1.6A 1A 1A 10A Catalogue Number 700S-CF Mechanical Life Electrical Life 20A 8 kW 14 kW 24 kW 6A Weight Terminal CrossSections Terminal Type 12A 9A 3.5A 0.55A 0.2A 9A 5A 2A 0.4A 0.16A 5A 3A 1.2A 0.6A 0.15A Solid Max. Wire Size per UL/CSA Tightening Torque Tightening Torque Terminal Size per IEC 60947-1 Flex. with Wire End Ferrule 2 x A4 AC-15 (240V, 3A) AC Op. Mechanism [Mil] [Mil] [g] 15 1.5 390 Left side aux. Right side aux.
Yes!
State of N.C. Contacts if N.O. contact welds Main Open Open Open ! Open ! Front aux. Open Open Open Open
A600, P600
10 mA 10A 10A 10A 10A 6A 2.5A 1A 1A 20A 8 kW 14 kW 24 kW
! Side-mounted auxiliary contacts provide "mirror contact" performance. Defined in IEC 60947-5-1 annex L. Positive guidance is a relationship between contacts of opposite types (i.e., N.O. and N.C.)
General
Aux. Contact (Frontmntd.) 15 1.5 -
Ith 230V 400V 690V
12A 9A 3.5A 0.55A 0.2A 9A 5A 2A 0.4A 0.16A 5A 3A 1.2A 0.6A 0.3A
2 x A4
48V 110V 220V 440V
/R < 1ms, Resistive Loads
1 Conductor 2 Conductor
[mm2] [mm2]
1...4 1...4
0.5...2.5 0.75...2.5
DC-14
L
24V 48V 110V 220V 440V 24V 48V
/R < 15ms, Inductive
1 Conductor 2 Conductor
[mm2] [mm2] [AWG] [lb-in] [Nm]
1.5...6 1.5...6 16...10 8.9...22 1...2.5
0.5...2.5 0.75...2.5 18...14 8.9...13.3 1...1.5
Loads with economy resistor in series
DC-13 Switching electromagnets
110V 220V 440V
9-20
Contactors & Control Relays
Safety Control Relays
100S-C and 700S-CF General (continued)
Aux.Contact (Side-mounted) Contact Ratings -- IEC AC-15 (solenoids, contactors) at rated voltage IEC 60947 120V 240V 400V 500V AC-12 (Non-inductive, or 40C slightly inductive loads, resistance furnaces), IEC60947 60C DC-13 (Solenoids and contactors), IEC60947 Ith Ith 24V 48V 110V 220V 440V Max. Wire Size per UL/CSA Tightening Torque Tightening Torque [AWG] [lb-in] [Nm] 6 5 3 1.6 10A 6A 3A 1.5A 0.6A 0.3A 0.2A 18...14 8.9...13.3 1...1.5
General (continued)
Catalogue Number 700S-CF Rated Insulation Voltage Ui IEC UL; CSA Rated Impulse Strength Uimp High Test Voltage 1 minute (per IEC 947-4) Rated Voltage Ue AC DC Short-Circuit Protection IEC 1581 Fuse, gG Rated Frequency Ambient Temperature Storage Operation at nominal current Conditioned 15% current reduction after AC-1 at > 60C Corrosion Resistance Catalogue Number 700S-CF -55...+80 C (-67...176 F) -25...+60 C (-13...140 F) -25...+70 C (-13...158 F) humid-alternating climate, cyclic, per IEC 68-2-30 and DIN 50 016, 56 cycles 2000m above mean sea level, per IEC 60947-4 115, 230, 400, 500, 690V 24, 48, 110, 220, 440V 10A 50/60 Hz, DC 2500V 690V 600V 8 kV
Control Circuit
Altitude Type of Protection
Operating Voltage AC 50/60 Hz Pick-up Dropout DC! Pick-up Dropout Coil Consumption AC 50/60 Hz Inrush Seal DC Operating Times AC 50/60 Hz Pick-up Time Dropout Time DC Pick-up Time Dropout Time [ms] [ms] [ms] [ms] 15...30 10...60 40...70 7...15 Inrush/Seal [VA/W] [VA/W] [W] 70/50 8/2.6 6.5 [x Us] [x Us] [x Us] [x Us] 0.85...1.1 0.3...0.6 0.8...1.1 0.1...0.6
IP 2X (IEC 529 and DIN 40050) Finger Protection
in connected state safe from touch by fingers and back of hand per VDE 0106, Part 100
! For 9V DC, code ZR, use operating voltage 0.65...1.3 x Us. For 24V DC, code ZJ or DJ, use operating voltage 0.7...1.25 x Us.
9-21
Contactors & Control Relays
Safety Control Relays
100S-C and 700S-CF Auxiliary Contacts
For Use With Catalogue Number Catalogue Number
Description
NO
NC
Connection Diagrams
-SA10
-4 -3 -3 -4
2
0
-SA20
1
0
-SB10
34 13 23 44
2
0
-SB20
! AC Coils: Max. 2 N.O. auxiliary contacts may be mounted on the side. DC coils: Max. 1 N.O. auxiliary contact may be mounted on the side. No additional N.C. auxiliary
contacts may be added to safety contactors and control relays listed in this publication. For additional contact configurations, consult your local Rockwell Automation/AllenBradley distributor. Double Numbering -- Left-side mounting only is recommended for Catalogue Number 700S-CF... due to double numbering.
Marking Systems
Uniform labelling materials for contactors, motor starting equipment, timing relays and circuit breakers
Description Label Sheet * Sheet with 105 self-adhesive paper labels, 6 x 17 mm Marking Tag Sheet * Sheet with 160 perforated paper labels, 6 x 17 mm * To be used with a transparent cover Transparent Cover * To be used with marking tag sheets Marking Tag Adaptors * 100 each * To be used with marking tag: System V4/V5 System Bul. 1492W Package Qty. 10 Catalogue Number 100-FMS
9-22
33
14
44
43
43
Auxiliary Contact Blocks for Side Mounting with Sequence Terminal Designations ! * 1- and 2-pole * Two-way numbering for right or left mounting on the contactor * Quick and easy mounting without tools * Electronic compatible contacts down to 17V, 10mA * L = Late break/Early make
13
14
-3
-4
-3
-3
Auxiliary Contact Blocks for Side Mounting without Sequence Terminal Designations ! * 1- and 2-pole * Two-way numbering for right or left mounting on the contactor * Quick and easy mounting without tools * Electronic-compatible contacts down to 17V, 10mA
-3
1
0
-4
-4
100S-C all 700S-CF all
100-SA10
-4
100S-C AC only 700S-CF AC only
100-SA20
100S-C09...C23 700S-CF all
100-SB10
24
100S-C09...C23 AC only 700S-CF AC only
100-SB20
10
100-FMP
100 100 100
100-FMC 100-FMA1 100-FMA2
Contactors & Control Relays
Safety Control Relays
100S-C and 700S-CF Control Modules
Connection Diagrams For Use With Catalogue Number Catalogue Number
Description DC Interface (electronic) * Interface between the DC control signal (PLC) and the contactor AC operating mechanism * Control voltage 18...30V DC (24V DC nominal) * For coil voltage of 110... 240V AC * Suitable for all 100S-C contactor sizes, 9...85 A * Requires no additional surge suppression for the coils * Power consumption - 0.1 W at 18V DC - 0.25 W at 24V DC - 0.5 W at 30V DC RC Module AC Operating Mechanism Varistor Module AC/DC Operating Mechanism Diode Module DC Operating Mechanism 24...48V, 50/60 Hz 110...280V, 50/60 Hz 380...480V, 50/60 Hz 12...55V AC/12...77V DC 56...136V AC /78...180V DC 137...277V AC /181...350V DC 278...575V AC 12...250V DC
K1M
100S-C with AC coils 700S-CF with AC coils
(K1M)
100-JE
Surge Suppressors For limitation of coil switching transients. * Plug-in, coil mounted * Suitable for all 100S-C contactor sizes, 9...85 A * RC, Varistor and Diode Versions
100S-C with AC coils 700S-CF with AC coils
100-FSC48 100-FSC280 100-FSC480 100-FSV55 100-FSV136 100-FSV277 100-FSV575
100S-C all 700S-CF all
100S-C with DC coils 100-FSD250 700S-CF with DC coils
9-23
Contactors & Control Relays
Safety Control Relays
100-D Auxiliary Contacts
Connection Diagrams For Use with Catalogue Number 100-D Left or right outside mounting
53 63
Description
NO
NC
Catalogue Number
1 * Side-mounted * With IEC sequence terminal designations 2
1
100-DS2-11
0
73 83 54 64
* Electronically compatible auxiliary contacts * Ideal for use when switching low-power control circuits * Contact ratings: AC-1 250V, 0.1 A AC-15, DC-13 3...125V, 1...100V,
1
1
Labeling Material
* Uniform labeling materials for contactors, motor protection devices, timing relays, and circuit breakers.
Marking Systems (for 100-D95...D860 contactors)
Description Label Sheet * 10 sheets with 105 self-adhesive paper labels each, 6 x 17mm Marking Tag Sheet * 10 sheets with 160 perforated paper labels each, 6 x 17mm * To be used with a transparent cover Transparent Cover * 100 each * To be used with marking tag sheets Marking Tag Adaptors * 100 each * To be used with marking tag: System V4/V5 System Bul. 1492W Package Qty. 10 Catalogue Number 100-FMS
9-24
74 84
100-D Left or right outside mounting
100-DS2-20
100-D Left or right outside mounting
100-DS2-B11
10
100-FMP
100
100-FMC
100 100
100-FMA1 100-FMA2
Contactors & Control Relays
Safety Control Relays
100S-C and 700S-CF Auxiliary Contacts
Internal Auxiliary Contacts Catalogue Numbers 100S-C09...100S-C23 Current Switching AC-12 Ith AC-15 at Rated Operating Voltage DC-13 at Rated Operating Voltage Continuous Current Rating per UL/CSA AC DC Short-Circuit Protection gG Fuse Type 2 Coordination Rated Impulse Voltage Uimp Insulation Voltage (between control and load circuit) per DIN, VDE 0106, Part 101 (NAMUR recommendation) [A] [A] 10A, 600V (NEMA A600) 5A, 600V (NEMA P600) 10A, 600V (NEMA A600) 2.5A, 600V (NEMA Q600) at 40C at 60C [A] [A] [V] [A] [V] [A] 10 10 10 10 5 2 25 20 24 48 120 240 400 415 500 690 6 5 2.5 1 24 48 110 220 400 0.7 0.25 0.12 6 5 6 2 6 5 10 6 24 48 120 240 400 415 500 690 3 2.5 1.6 1 24 48 110 220 400 0.7 0.25 0.12 Side-Mounted Auxiliary Contacts Catalogue Numbers 100-SA, 100-SB, 100-MC
[A] [kV] [V]
10 8 250 17V, 10mA
10 6 500 17V, 10mA 100-SA, 100-SB: Mirror output performance per IEC60947-4 Annex F 100-MC: Mutually unrestricted between all N.O. and N.C. contacts
Contact reliability per DIN 19240 without contamination, normal industrial atmosphere Mechanically Linked Contacts per IEC 60947-5-1 Annex L (SUVA Third-party certified) Terminals Terminal Type Wire Size per IEC 60947-1 Flexible w/Wire-End Ferrule 1 Conductor 2 Conductor Solid/Stranded Conductor 1 Conductor 2 Conductor Recommended Tightening Torque (min...max) Wire Size per UL/CSA Recommended Tightening Torque (min...max) [mm2] [mm2] [mm ] [mm2] Nm [AWG] [lb-in]
2
Mutually unrestricted between all N.O. and N.C. contacts
2 x A4
2 x A4
1...4 1...4 1.5...6 1.5...6 1...2.5 16...10 8.9...22
0.5...2.5 0.75...2.5 0.5...2.5 0.75...2.5 1...1.5 18...14 8.9...13.3
9-25
Contactors & Control Relays
Safety Control Relays
100-DS2 Auxiliary Contacts
Side-Mounted Auxiliary Contacts Catalogue Numbers 100-DS2 Conventional Current Switching AC-12 Ith AC-15 at Rated Operating Voltage at 40C at 60C [A] [A] [V] [A] DC-13 at Rated Operating Voltage Continuous Current Rating per UL/CSA AC DC Short-Circuit Protection gG Fuse Type 2 Coordination Rated Impulse Voltage Uimp Insulation Voltage (between control and load circuit) per DIN, VDE 0106, Part 101 (NAMUR recommendation) [A] [A] 10A, 600V (NEMA A600) 2.5A, 600V (NEMA Q600) [V] [A] 16 12 230 240 400 415 500 690 5.5 5 3 2.5 1.6 1 1... 100mA at 3... 125V 0.1 at 250V Electronically Compatible
24 48 110 220 440 5 2 0.7 0.25 0.12
[A] [kV] [V]
10 8
--
Contact reliability per DIN 19240 without contamination, normal industrial atmosphere Mechanically Linked Contacts per IEC 60947-5-1 Annex L (SUVA Third-party certified) Terminals Terminal Type Wire Size per IEC 60947-1 Flexible w/Wire-End Ferrule 1 Conductor 2 Conductor Solid/Stranded Conductor 1 Conductor 2 Conductor Recommended Tightening Torque (min...max) Wire Size per UL/CSA Recommended Tightening Torque (min...max) [mm2] [mm2] [mm2] [mm2] Nm [AWG] [lb-in]
17V, 5mA Mirror contact performance per IEC 60947-4 Annex F
17V, 1mA Mirror contact performance per IEC 60947-4 Annex F
2 x A4
2 x A4
1...2.5 1...2.5 1...4 1...4 1.4...2.3 16...12 12...20
1...2.5 1...2.5 1...4 1...4 1.4...2.3 16...12 12...20
9-26
Contactors & Control Relays
Safety Control Relays
100S-C and 700S-CF Dimensions--mm (inches)
Dimensions are not intended for manufacturing purposes.
Mounting Position
c2
AC Contactors and Control Relays
c1 c
DC Contactors and Control Relays
AC Contactors and Control Relays
a 45 (1-25/32) 45 (1-25/32) 54 (2-1/8) 72 (2-53/64) b 81 (3-3/16) 81 (3-3/16) 81 (3-3/16) 122 (4-51/64) c 119.5 (4-3/4) 136.5 (5-37/64) 139.5 (5-11/16) 156 (6-11/32) c1 114.5 (4-43/64) 131.6 (5-11/32) 134.6 (5-29/64) 150.5 (6-1/8) c2 6 (1/4) 6.5 (17/64) 6.5 (17/64) 8.5 (21/64) d 2 - 4.5 (2 - 3/16) 2 - 4.5 (2 - 3/16) 2 - 4.5 (2 - 3/16) 4 - 5.4 (4 - 7/32) d1 60 (2-23/64) 60 (2-23/64) 60 (2-23/64) 100 (3-15/16) d2 35 (1-25/64) 35 (1-25/64) 45 (1-25/32) 55 (2-11/64) Catalogue Number 100S-C09...100S-C23, 700S-CF 100S-C30, 100S-C37 100S-C43 100S-C60...100S-C85
DC Contactors and Control Relays
a 45 (1-25/32) 45 (1-25/32) 45 (1-25/32) 54 (2-1/8) 72 (2-53/64) b 81 (3-3/16) 81 (3-3/16) 81 (3-3/16) 81 (3-3/16) 122 (4-51/64) c 145.5 (5-49/64) 162.5 (6-7/16) 180.5 (7-5/32) 183.5 (7-17/64) 156 (6-11/32) c1 140.5 (5-37/64) 158 (6-1/4) 175.5 (6-61/64) 179 (7-3/32) 150.5 (6-1/8) c2 6 (1/4) 6 (1/4) 6.5 (17/64) 6.5 (17/64) 8.5 (21/64) d 2 - 4.5 (2 -3/16) 2 - 4.5 (2 -3/16) 2 - 4.5 (2 -3/16) 2 - 4.5 (2 -3/16) 4 - 5.4 (4 -7/32) d1 60 (2-23/64) 60 (2-23/64) 60 (2-23/64) 60 (2-23/64) 100 (3-15/16) d2 35 (1-25/64) 35 (1-25/64) 35 (1-25/64) 45 (1-25/32) 55 (2-11/64) Catalogue Number 100S-C09Z...100S-C16Z, 700SCF 100S-C23Z 100S-C30...100S-C37 100S-C43Z 100S-C60D...100S-C85D
Accessories
Contactors with Auxiliary contact block for side mounting 1- or 2-pole Electronic Timing Module on coil terminal side Mechanical Interlock on side of contactor Interface Module on coil terminal side Surge Suppressor on coil terminal side Labelling with label sheet marking tag sheet with clear cover marking tag adapter for System V4/V5 marking tag adapter for System Bul. 1492W mm a+9 b + 24 a+9 b+9 b+3 +0 +0 + 5.5 + 5.5 (inches) (a + 23/64) (b + 15/16) (a + 23/64) (b + 23/64) (b + 1/8) (+ 0) (+ 0) (+ 7/32) (+ 7/32)
9-27
Contactors & Control Relays
Safety Control Relays
100S-D Contactors and Accessories Dimensions--mm (inches)
Dimensions are not intended for manufacturing purposes.
Mounting Position
e2 e1 oe c1 e4 d1 od d2 a c
Catalogue Number 100S-D95, 100S-D110 100S-D95-EI...100S-D180-EI, 100S-D140, 100S-D180 100S-D210-EI...100S-D420-EI 100S-D630-EI...100S-D860-EI
a 120 120 155 255
b 170 170 205 310
c 156 156 180 265
e3
b
c1 110.5 110.5 110.5 110.5
od 5.2 5.2 6.5 10
d1 145 145 180 230
d2 100 100 130 225
oe M6 M8 M10 M12
e1 16 20 25 40
e2 38.5 39 48 70
e3 147 160 193 291
e4 8 10 12.5 22
Contactor with Auxiliary contact block Mechanical interlock Frame terminal block Label holder 100-DS2... 100-DM... 100-DTB110 100-DTB180 100-DTB420
[mm] a + 13.5 each a+a b + 7 each b + 7 each b + 8.5 each c...+ 5
Convention DC coil contactors will have an additional auxiliary contact block mounted which will add 13.5mm (0.53in) to the "a" dimension on the right hand side.
9-28


▲Up To Search▲   

 
Price & Availability of 700S-CF

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X